METALSKIN
ΕΡΓΑ
ΠΡΟΙΟΝΤΑ
DESIGN MESHES
XPAND
PERFORATED
WAVE
HEXCEL
GATES FENCES
LINEAR SERIES
BLIND SERIES
CUBIC SERIES
CLASSIC SERIES
TAILOR MADE SOLUTIONS
FIN SERIES
PLAY SERIES
RAILING SYSTEMS
FUSION LINE
SYNTHESIS
VERTICAL
CLASSIC LINE
CLS EDITION
ALFLEX EDITION
PSATHA EDITION
ΑΡΧΕΙΑ
ΝΕΑ
ΕΠΙΚΟΙΝΩΝΙΑ
Search
Main menu
SERIES
LAB
SPECIMEN DESCRIPTION
REPORT
LAN
DATE
Tech Catalogues
DWG files
25
A.U.T
FIXED WINDOW DOUBLE
GLASS 1230x1480
Rw (C;Ctr): 39 (-2;-4) dB
GR, EN
12.01.2023
25
A.U.T
FIXED WINDOW SINGLE
GLASS 1230x1480
Rw (C;Ctr): 38 (-2;-4) dB
GR, EN
12.01.2023
25
A.U.T
FIXED WINDOW
STRUCTURAL GLASS
1230x1480
Rw (C;Ctr): 40 (-3;-9) dB
GR, EN
12.01.2023
75
IFT ROSENHEIM
SINGLE LEAF
Uf=1.5-1.7 W/m²K
EN
09.08.2017
PIVOT DOOR
Up=0.27 W/m²K
09.08.2017
2000x3000
Ud=0.79 W/m²K
10.08.2017
75
IFT ROSENHEIM
DOUBLE LEAF EXT
AIR: CLASS 3
EN, DE
06.03.2019
PEDESTRIAN DOORSET
WATER: CLASS 5A
WITH OMS 2000x2400
WIND: CLASS C1/B1
75
A.U.T
DOOR 1210x1470
Rw (C;Ctr): 44 (-1;-4) dB
GR, EN
13.09.2018
75
IFT ROSENHEIM
SINGLE LEAF
BURGLAR RESISTANCE: CLASS RC2
EN, DE
25.10.2021
EXT PEDESTRIAN DOORSET
1000x2200
90
IFT ROSENHEIM
SINGLE LEAF
Uf=1.6-1.8 W/m²K
EN
09.08.2017
PANEL DOOR
Uf,Edge=1.5-2.2 W/m²K
09.08.2017
1300x2500
Up=0.33-0.44 W/m²K
09.08.2017
Ud=0.79 W/m²K
10.08.2017
90
IFT ROSENHEIM
SINGLE LEAF
BURGLAR RESISTANCE: CLASS RC2
EN, DE
13.10.2021
EXT PEDESTRIAN DOORSET
1000x2200
110
IFT ROSENHEIM
SINGLE LEAF
Uf,Edge=2.2-2.8 W/m²K
EN
09.08.2017
PIVOT DOOR
Up=0.27 W/m²K
09.08.2017
2000x3000
Ud=0.69 W/m²K
10.08.2017
4900
PASSIVE HOUSE
WINDOW
Uw=0.78 W/m²K
EN
31.12.2017
INSTITUTE
1230x1480
Uf=0.76 W/m²K
4900
TECNO
DOUBLE LEAF
AIR: CLASS 3
IT
31.08.2022
PIEMONTE
1230x1480
WATER: CLASS 6A
WIND: CLASS C4
4900
A.U.T
FIXED WINDOW
Rw (C;Ctr): 52 (-2;-4) dB
GR, EN
29.03.2023
1230x1480
4900
A.U.T
TILT & TURN WITH FIXED
Rw (C;Ctr): 50 (-5;-13) dB
GR, EN
29.03.2023
2900x2600
4750
IFT ROSENHEIM
Uf=1.2-2.3 W/m²K
EN, DE
16.04.2018
4750
IFT ROSENHEIM
DOUBLE TILT AND TURN
AIR: CLASS 4
EN, DE
17.08.2018
CASEMENT DOOR WITH
WATER: CLASS 3A
OPENING CENTRAL
WIND: CLASS C2/B2
MEETING STILE 1400x2200
4750
IFT ROSENHEIM
DOUBLE TURN CASEMENT
AIR: CLASS 4
EN, DE
23.01.2019
DOOR WITH OPENING
WATER: CLASS 8A
MEETING STYLE 1400x2200
WIND: CLASS C3/B3
4750
IFT ROSENHEIM
SIDE HUNG WINDOW WITH
AIR: CLASS 4
EN, DE
14.04.2020
FIXED LIGHT
WATER: CLASS E1200
1600x1400
WIND: CLASS C5/B5
4750
A.U.T
FIXED WINDOW
Rw (C;Ctr): 39 (-2;-7) dB
GR, EN
07.07.2020
1230x1480
4750
UL CLEB (USA)
FIXED WINDOW
NAFS PERFORMANCE
EN
03.10.2018
1500x2500
CLASS AW-PG90
4750
UL CLEB (USA)
CASEMENT WINDOW
NAFS PERFORMANCE
EN
15.10.2018
900x1500
CLASS AW-PG100
4750
UL CLEB (USA)
CASEMENT WINDOW 600x1500
THERMAL TRANSMITTANCE
EN
18.01.2019
SERIES
LAB
SPECIMEN DESCRIPTION
REPORT
LAN
DATE
4750
UL CLEB (USA)
FIXED WINDOW 1200x1500
THERMAL TRANSMITTANCE
EN
18.01.2019
Us 2.21 W/m²K 0.39 BTU (hr.ft².F)
450
UL CLEB (USA)
COMBINATION WINDOW
NAFS PERFORMANCE
EN
02.03.2018
2325x2340
CLASS CW-PG55
450
UL CLEB (USA)
DUAL ACTION
NAFS PERFORMANCE
EN
21.12.2017
COMPOSITE WINDOW
CLASS CW-PG40
2245x1735
CLASS CW-PG55
450
UL CLEB (USA)
CASEMENT WINDOW
NFRC VALIDATION
EN
19.12.2017
600x1500
Us:2.51±0.08W/(m²C) (0.44±0.01 BTU/
(hrft2F)
Ust:2.42±0.08W/(m²C) (0.43±0.01 BTU/
(hrft2F)
450
UL CLEB (USA)
CASEMENT WINDOW
NFRC SIMULATION
EN
13.11.2017
600x1500
U:2.57W/m²K 0.45 BTU (hr.ft2.F)
450
UL CLEB (USA)
FIXED WINDOW
NFRC VALIDATION
EN
19.12.2017
1200x1500
Us:1.98±0.08W/(m²C) (0.35±0.01 BTU/
(hrft2F)
Ust:1.94±0.08W/(m²C) (0.34±0.01 BTU/
(hrft2F)
450
UL CLEB (USA)
FIXED WINDOW
NFRC SIMULATION
EN
10.11.2017
1200x1500
U:1.87W/m²K 0.33 BTU (hr.ft2.F)
450
UL CLEB (USA)
DUAL ACTION TILT & TURN
NFRC SIMULATION
EN
18.04.2017
WINDOW 1200x1500
U:2.07W/m²K 0.36 BTU (hr.ft2.F)
450
UL CLEB (USA)
DUAL ACTION WINDOW
NAFS PERFORMANCE
EN
09.03.2017
1200x1800
CLASS CW-PG45
450
IFT ROSENHEIM
SINGLE LEAF EXTERNAL
AIR: CLASS 3
EN
28.02.2017
PEDESTRIAN DOORSET
WATER: CLASS 6A
1000x2200
WIND: CLASS C4/B4
450
IFT ROSENHEIM
DOUBLE COMBINED SIDE-
DEFLECTION: ± 600 Pa
EN
15.02.2017
AUS
HUNG AND TILT&TURN
AIR INFILTRATION= ± 75 Pa
STANDARDS
WINDOW WITH OPENING
WATER RESISTANCE= 300 Pa
MEETING STYLE 1500x2300
ULTIMATE STRENGTH: ± 1.400 Pa
450
IFT ROSENHEIM
SINGLE TILT & TURN
AIR: CLASS 4
EN
10.02.2017
WINDOW WITH FIXED TOP
WATER: CLASS 7A
LIGHT 900x1500
WIND: CLASS C5/B5
450
IFT ROSENHEIM
DOUBLE COMBINED SIDE-
AIR: CLASS 4
EN
07.02.2017
HUNG AND TILT & TURN
WATER: CLASS 8A
WINDOW WITH OPENING
WIND: CLASS C4/B4
MEETING STYLE 1400x2200
450
IFT ROSENHEIM
HORIZONTAL PIVOT
AIR: CLASS 4
EN
03.02.2017
CASEMENT 1400x1400
WATER: CLASS 7A
WIND: CLASS B4
450
A.U.T
SINGLE TILT & TURN
Rw (C;Ctr): 43 (-2;-7) dB
GR, EN
10.07.2015
WINDOW 1260x1480
450 HS
IFT ROSENHEIM
SINGLE TILT & TURN
AIR: CLASS 4
EN
03.02.2017
WINDOW WITH FIXED SIDE
WATER: CLASS 7A
LIGHT 2000x2200
WIND: CLASS B4
450 HS
IFT ROSENHEIM
Uf=1.6-2.8 W/m²K
EN, DE
08.05.2015
540
FCG TESTING
TILT&TURN WINDOW WITH
2500/2500 Pa Pos/Neg Serviceability
EN
29.08.2018
LABORATORY
BOTTOM FIXED PANEL
and 2750/8000 Pa Pos/Neg Ultimate
AUS
1060x2200
Rating
STANDARDS
150 Pa Water Penetration Rating
SERIES
LAB
SPECIMEN DESCRIPTION
REPORT
LAN
DATE
540
FCG TESTING
AWNING WITH BOTTOM
2500/2500 Pa Pos/Neg Serviceability
EN
29.08.2018
LABORATORY
FIXED PANEL
and 3700/5300 Pa Pos/Neg Ultimate
AUS
1060x2200
Rating
STANDARDS
600 Pa Water Penetration Rating
Passed Opening Forces and Air-
conditioned Applications
200
IFT ROSENHEIM
SINGLE LEAF SLIDING
AIR: CLASS 3
EN
30.06.2014
WINDOW 1200x2200
WATER: CLASS 3A
WIND: CLASS C3/B3
200
IFT ROSENHEIM
DOUBLE SASH SLIDING
AIR: CLASS 3
EN
15.12.2016
WINDOW 1605x2203
WATER: CLASS 3A
WIND: CLASS C1/B2
200
IFT ROSENHEIM
DOUBLE LEAF SUCCESSIVE
AIR: CLASS 3
EN
30.06.2014
1600x2200
WATER: CLASS 3A
WIND: CLASS C1/B2
200
A.U.T
SLIDING OVERLAPPING
Rw (C;Ctr): 26 (-0;-1) cdB
GR, EN
14.07.2015
WINDOW 1230x1480
200
IFT ROSENHEIM
Uf=2.1-5.1 W/m²K
DE
26.09.2013
320
IFT ROSENHEIM
LIFTING SLIDING DOOR
AIR: CLASS 4
EN
15.12.2020
2600x2400
WATER: CLASS 7A
WIND: CLASS C3/B4
2900
IFT ROSENHEIM
Uf=2.0-4.5 W/m²K
EN
04.07.2017
2900
IFT ROSENHEIM
SINGLE SASH
OF: CLASS 1
EN, DE
07.02.2017
SLIDING DOOR WITH FIXED
AIR: CLASS 2
LIGHT 2000x2200
WATER: CLASS 2A
WIND: CLASS C3/B3
2700
IFT ROSENHEIM
DOUBLE LIFTING SLIDING
OF: CLASS 1
EN, DE
05.05.2021
SASH 2600x2400
AIR: CLASS 4
WATER: CLASS 9A
WIND: CLASS B4
2700
A.U.T
DOUBLE LIFTING SLIDING
Rw (C;Ctr): 42 (-0;-3) cdB
GR, EN
22.06.2021
WINDOW STANDARD FRAME
2000x2200
2700
A.U.T
DOUBLE LIFTING SLIDING
Rw (C;Ctr): 41 (-1;-4) cdB
GR, EN
22.06.2021
WINDOW LOW FRAME
WITH NARROW INTERLOCK
2000x2200
2700
IFT ROSENHEIM
Uf=1.7-8.1 W/m²K
EN, DE
15.12.2019
2450
IFT ROSENHEIM
Uf=1.9-5.3 W/m²K
EN
11.04.2018
2450
IFT ROSENHEIM
SINGLE SASH
OF: CLASS 1
EN
23.02.2018
LIFTING-SLIDING DOOR
AIR: CLASS 4
WITH FIXED SIDELIGHT
WATER: CLASS 3A
2000x2200
WIND: CLASS C4/B4
2450
A.U.T
WINDOW 1210x1470
Rw (C;Ctr): 40 (-2;-7) dB
GR, EN
13.09.2018
4600
IFT ROSENHEIM
Uf=2.1-3.1 W/m²K
EN
29.03.2017
4600
IFT ROSENHEIM
TRIPLE SASH BI-FOLDING
AIR: CLASS 3
EN
09.02.2017
DOOR
WATER: CLASS 2A
WIND: CLASS C3/B4
4600
IFT ROSENHEIM
Uf=2.1-3.1 W/m²K
3300
IFT ROSENHEIM
GLASS LOUVRE SYSTEM
WATER: CLASS 2A
EN
23.02.2018
SERIES
LAB
SPECIMEN DESCRIPTION
REPORT
LAN
DATE
750
PLANECO
ROLLER SHUTTER
WIND (EN13659:2004+A1:2008): CLASS
EN
18.10.2018
2800x2500
6
WIND (EN13659:2015): CLASS 6
750
PLANECO
ROLLER SHUTTER
WIND (EN13659:2004+A1:2008): CLASS
EN
18.10.2018
1405x2400
6
WIND (EN13659:2015): CLASS 6
50
IFT ROSENHEIM
STICK CURTAIN WALL
AIR: CLASS AE
EN
02.02.2021
3000x3600
WATER: CLASS RE 1200
WIND: Design load: ±1600 Pa,
Safety load: ±1600 Pa
50SP
A.U.T
FIXED CURTAIN WALL
Rw (C;Ctr): 52 (-3;-7) dB
GR, EN
20.09.2008
3674x3074
50SP
IFT ROSENHEIM
Uf=1.64 W/m²K
EN
20.09.2008
NEW
W&D
A.U.T
ALUMINIUM PANEL
Rw (C;Ctr): 40 (-2;-6) dB
GR, EN
12.01.2023
3690x3080
04/5/2023
ΕΣΩΤΕΡΙΚΗ ΕΝΗΜΕΡΩΣΗ
REPORT: ΝΈΕΣ ΠΙΣΤΟΠΟΙΉΣΕΙΣ ΚΑΓΚΕΛΑ
SERIES
LAB
SPECIMEN
REPORT
LAN
DATE
DESCRIPTION
OPEN AIR
INTERTEK USA
ULTRA PLUS
ACHIEVED CONCENTRATED LOAD
EN
19.03.2018
1300x1000
WITHOUT FAILURE IN ACCORDANCE
WITH 2015, INTERNATIONAL
RESIDENTIAL CODE 806lb=3.6KN
NEW
CRYSTAL
CSTB
SLIM LINE HD
FULFILLED MAXIMUM LOAD OF 3KN
FR
04.11.2022
LINE
NEW
CRYSTAL
CSTB
L-LINE TOP MOUNT
FULFILLED MAXIMUM LOAD OF 3KN
FR
04.11.2022
LINE
CRYSTAL
IFT
SLIM LINE HD
FULFILLED MAXIMUM LOAD OF 1.84KN
EN
26.04.2021
LINE
ROSENHEIM
2000x1200 GLASS
17.52MM
CRYSTAL
IFT
SLIM LINE HD
FULFILLED MAXIMUM LOAD OF 1.84KN
EN
26.04.2021
LINE
ROSENHEIM
2000x1200 GLASS
21.52MM
CRYSTAL
IFT
SLIM LINE SIDE
FULFILLED MAXIMUM LOAD OF 1.84KN
EN
30.04.2020
LINE
ROSENHEIM
MOUNT 2050x1380
GLASS 21.52MM
CRYSTAL
IFT
SLIM LINE
FULFILLED MAXIMUM LOAD OF 1.84KN
EN
13.07.2018
LINE
ROSENHEIM
2000x1200
TL GLASS 13.54 (66.4PVB)
CRYSTAL
IFT
SLIM LINE
FULFILLED MAXIMUM LOAD OF 1.84KN
EN
13.07.2018
LINE
ROSENHEIM
2000x1200
TL GLASS 17.51 (88.4PVB)
CRYSTAL
INTERTEK USA
L-LINE TOP MOUNT
ACHIEVED CONCENTRATED LOAD
EN
19.03.2018
LINE
F85-1B62
WITHOUT FAILURE IN ACCORDANCE
1000x1300
WITH 2015, INTERNATIONAL BUILDING
GLASS 21.52 (10.4.10)
CODE 804lb=3.6KN
CRYSTAL
INTERTEK USA
L-LINE TOP MOUNT
ACHIEVED CONCENTRATED LOAD
EN
19.03.2018
LINE
F85-1B63
WITHOUT FAILURE IN ACCORDANCE
1000x1300
WITH 2015, INTERNATIONAL BUILDING
GLASS 21.52 (10.4.10)
CODE 807lb=3.6KN
CRYSTAL
INTERTEK USA
L-LINE SIDE MOUNT
ACHIEVED CONCENTRATED LOAD
EN
19.03.2018
LINE
F85-1B64
WITHOUT FAILURE IN ACCORDANCE
1000x1300
WITH 2015, INTERNATIONAL BUILDING
GLASS 21.52 (10.4.10)
CODE 807LB=3.6KN
CRYSTAL
BBRI BELGIUM
L-LINE TOP MOUNT
ACHIEVED DISTRIBUTED LOAD WITHOUT
EN
30.08.2017
LINE
F85-1B63, F85-1B62
FAILURE OF 3.6KN/M
1000x1200
GLASS 1212.4 DG41
NEW
FUSION LINE
IFT
FUSION LINE
FULFILLED MAXIMUM LOAD OF 1.84KN
EN
18.11.2022
ROSENHEIM
ORBIT-2 TOP MOUNT
2710x1200
NEW
FUSION LINE
IFT
FUSION LINE ORBIT-2
FULFILLED MAXIMUM LOAD OF 1.84KN
EN
18.11.2022
ROSENHEIM
SIDE MOUNT
2710x1400
NEW
FUSION LINE
IFT
FUSION LINE
FULFILLED MAXIMUM LOAD OF 1.84KN
EN
18.11.2022
ROSENHEIM
ORBIT-1 TOP MOUNT
2710x1200
NEW
FUSION LINE
IFT
FUSION LINE ORBIT-1
FULFILLED MAXIMUM LOAD OF 1.84KN
EN
18.11.2022
ROSENHEIM
SIDE MOUNT
2710x1400
04/5/2023
ΕΣΩΤΕΡΙΚΗ ΕΝΗΜΕΡΩΣΗ
REPORT: ΝΈΕΣ ΠΙΣΤΟΠΟΙΉΣΕΙΣ ΚΑΓΚΕΛΑ
SERIES
LAB
SPECIMEN
REPORT
LAN
DATE
DESCRIPTION
NEW
F50
IFT
F50 HORIZON FRAME
Drop height 1200 mm: Passed
EN
31.03.2022
ROSENHEIM
2200x1210
F50
IFT
HORIZON FRAME -
Drop height 1200 mm: Passed
EN
29.08.2018
ROSENHEIM
EXTERNAL 2200x1210
TS Glass 10.76
(55.2PVB)
FUSION LINE
INTERTEK USA
ELXIS TYPE B
ACHIEVED CONCENTRATED LOAD
EN
28.08.2018
1000x1300
WITHOUT FAILURE IN ACCORDANCE
GLASS 21.52 (10.4.10)
WITH 2018, INTERNATIONAL BUILDING &
RESIDENTIAL CODE 502LB=2.23KN
FUSION LINE
IFT
SYNTHESIS TYPE B1
FULFILLED MAXIMUM LOAD OF 1.84KN
EN
13.07.2018
ROSENHEIM
2710x1200
TL GLASS 11.52 (55.4PVB)
FUSION LINE
INTERTEK USA
SYNTHESIS TYPE B1
ACHIEVED CONCENTRATED LOAD
EN
26.06.2018
1000x1300
WITHOUT FAILURE IN ACCORDANCE
GLASS 21.52 (10.4.10)
WITH 2018, INTERNATIONAL BUILDING &
RESIDENTIAL CODE 502LB=2.23KN
FUSION LINE
IFT
ELXIS TYPE C
FULFILLED MAXIMUM LOAD OF 1.84KN
EN
14.06.2018
ROSENHEIM
2710x1200
TL GLASS 11.52 (55.4PVB)
FUSION LINE
IFT ROSENHEIM
ORBIT 1 WITH HADRAIL
FULFILLED MAXIMUM LOAD OF 1.84KN
EN
14.06.2018
2710x1200
TL GLASS 13.52 (66.4PVB)
FUSION LINE
IFT
ELXIS TYPE B
FULFILLED MAXIMUM LOAD OF 1.84KN
EN
12.06.2018
ROSENHEIM
2710x1200
TL GLASS 11.52 (55.4PVB)
→
Μήνυμα
Φόρμα Μηνύματος
Όνομα
Τηλέφωνο
Email
Μήνυμα
Τηλέφωνο